beautypg.com

Toa SV-200MA User Manual

Page 40

background image

40

23.2. VM Amplifier's Internal Function Switches

The switches must be set by a qualified service technician only.
Each of the following functions can be selectively set with the switches.
For the switch setting method, refer to the separate instruction manual for qualified service technicians.

Priority levels (Underlined priority levels represent factory-preset levels.)

Priority modes, Unit type, and Number of units (Underlined settings represent factory-preset settings.)

BGM broadcast volume attenaution level (Underlined level represents factory-preset level.)

23.3. Remote Microphone's Function Switches

* One of 2 priorities can be set for each Remote microphone. (See p.26 "GENERAL-PURPOSE

BROADCAST PRIORITY.")

RM (RM-200M) Unit No. table

All switches No. 1 – 6 are factory-preset to the ON position.

6

Compressor

On

Off

1 2

ON

3 4 5 6

Function setting switch

Note
The switch is actually installed upside down.

Switch No.
Function

ON

OFF

1

2

RM Unit No.
(See the RM Unit No.
table below.)

3

Broadcast

Priority*

2

1

4

Talk key
operation
Press-to-talk
type
Talk lock type

5

Emergency
switch

Enable

Disable

RM Unit No.

No. 1
No. 2
No. 3
No. 4

Switch No.

1

2

ON

ON

OFF

ON

ON

OFF

OFF

OFF

Function

Input 1 Input 2 Input 3

Message 3 Message 4 Message 5

1 1 1

1

3

3

3

Selectable

2

2

2

2

1

1

1

Priority Mode
for Same
Priority Unit
Unit No. Priority
(Numerical order)
First/Last
Priority

Inputs 1 – 3
Broadcast Priority Level

Voice Announcement Board's
Message Priority Level

TEL Paging
Priority Level

Function

Mixed

Silent

On

Sub-unit

Selectable

(off)

Off

(on)

First/Last
Priority

First-come
first-served
Last-come
first-served

Not mixed

Evacuation
message

Master
unit

Priority 2
Mixing

Mode after
Emergency Talk

Input 3/LINE
(Input 3/MIC)
Chime On/Off

Unit Type

No. of Connected
Units

0 through 5

Function

BGM broadcast volume attenuation
No attenuation

Selectable –28 dB (just audible)

– ∞ dB (inaudible)

This manual is related to the following products: