TeeJet 834 Sprayer Control L2.12 User Manual

Page 6

background image

TECHNOLOGIES

834

Sprayer

Control

98-70019-R1 -6-

S

PEED

S

ENSOR

C

ALIBRATION

Default = 250 pulses/100 meters

The speed sensor needs to be calibrated in order
to provide the proper speed reading. The value
for this step is the number of pulses generated by
the speed sensor in 100 meters.

Auto Calibration

The speed sensor can be automatically calibrated
by driving 100 meters. The console will
automatically detect a RADAR sensor (if used).

To start the auto calibration procedure, press

simultaneously on the

+

and

keys. The

display now will show CAL.
Now you have to drive to the starting point of the

100 meter distance. Push the

+

key to start

counting speed pulses as you cross the start point.

Drive 100 meters and press

+

again to stop the pulse

counting as you cross the finish point.

Note: During the Auto calibration, each time a pulse is

recorded the Man LED will flash.


The number now on the display is the number of
pulses corresponding to 100 meters.

The auto calibration procedure can be escaped with

the key. The console will then return to the

previous calibration value.

Note: The auto speed calibration should be

repeated at least twice and an average of
the calibration numbers should be entered.