TeeJet 834 Sprayer Control L2.12 User Manual
Page 6
TECHNOLOGIES
834
Sprayer
Control
98-70019-R1 -6-
S
PEED
S
ENSOR
C
ALIBRATION
Default = 250 pulses/100 meters
The speed sensor needs to be calibrated in order
to provide the proper speed reading. The value
for this step is the number of pulses generated by
the speed sensor in 100 meters.
Auto Calibration
The speed sensor can be automatically calibrated
by driving 100 meters. The console will
automatically detect a RADAR sensor (if used).
To start the auto calibration procedure, press
simultaneously on the
+
and
keys. The
display now will show CAL.
Now you have to drive to the starting point of the
100 meter distance. Push the
+
key to start
counting speed pulses as you cross the start point.
Drive 100 meters and press
+
again to stop the pulse
counting as you cross the finish point.
Note: During the Auto calibration, each time a pulse is
recorded the Man LED will flash.
The number now on the display is the number of
pulses corresponding to 100 meters.
The auto calibration procedure can be escaped with
the key. The console will then return to the
previous calibration value.
Note: The auto speed calibration should be
repeated at least twice and an average of
the calibration numbers should be entered.
Man
Auto
CAL
D
I
3 sec. = Pro
250
CAL
D
I
3 sec. = Pro
cal
CAL
D
I
3 sec. = Pro
250