Programmable Tip

As mentioned above the _P section of the Tip
Selection Display can be programmed to match
the flow rate of the tips on the sprayer if they do
not fall into one of the categories listed above.
To access the programmable section, while viewing
the _P display, simulataneously press the
Auto/Man and keys for 3 seconds.







The display will then display a flashing flow rate
represented in l/min at 2 bar. The Tip Select

LED will also be flashing. Use the

+

and

keys to adjust this value so that it matches the flow
rate of one of your tips in l/min at 2 bar.

Note: It is critical that this flow rate be referenced at 2 bar for the controller to regulate the
application rate correctly.


Press the key to save the _P value and return to the Tip Select display.

CAL

D

I

3 sec. = Pro

_p

CAL

D

I

3 sec. = Pro

1.36