System Setup Mode

The System Setup Mode contains the programming steps that customize the monitor to the
sprayer or sprayer components. These include calibration steps and parameters that, once
programmed, will likely never change.

To enter the System Setup Mode:

First be sure that the console is ON (if not put it on by pressing the key and wait until
the normal display is visible).

Ensure the Master boom switch is OFF.

Then press and hold the key for 3 seconds to enter the System Setup Mode.

D

ENSITY

Default = 1.00

If a substance other than water is being sprayed
or used as a carrier (e.g. liquid fertilizer), enter
the density of that fluid.

Weight of

Weight of

Weight of

Weight of

Solution Per Gallon

Solution Per Gallon

Solution Per Gallon

Solution Per Gallon

Liquid

Liquid

Liquid

Liquid

Density

Density

Density

Density

7.0 lbs.

0.84

8.0 lbs.

0.96

8.34 lbs. - Water

1.00

10.0 lbs.

1.20

10.65 lbs. – 28% N

1.28

10.85 lbs. – 30% N

1.30

11.0 lbs.

1.32

12.0 lbs.

1.44

14.0 lbs.

1.68

Use the

+

or

keys to adjust this value. Once the correct units have been selected,

depress the key to advance to the next step.

Note: If the solution that you
are using can not be found in
the chart at left, the Liquid
Density can be calculated as
follows:

CAL

D

I

3 sec. = Pro

1.00

Density = Weight of Solution

Weight of Water

Note: Water weighs 1 Kg/L