Transmitting data – SUUNTO Vyper Air User Manual
Page 43
![background image](/manuals/713048/43/background.png)
5.6.3. Transmitting data
After the pairing procedure, the Suunto Vyper Air will receive cylinder pressure data
from the transmitter. The pressure is displayed in either bars or psi, depending on the
unit selected. Any time the Suunto Vyper Air receives an appropriate signal, the
wireless transmitter indicator is displayed in the lower left corner.
Table 5.4. Pressure transmission related displays
Figure
Indication
Display
A
Set Code. No code stored, Suunto Vyper Air ready for pairing with
transmitter.
Cd:--
B
Pressure reading over 360 bar/5220 psi.
- - -
C
Pressure reading has not been updated for more than one minute.
The latest valid pressure reading is displayed intermittently. After
five minutes, "FAIL" is displayed intermittently with "---".
Transmitter is out of range, in power saving mode or on another
channel. Activate the transmitter by breathing off the regulator,
and recode the wrist if necessary.
FAIL
D
Pressure transmitter battery voltage is low. The pressure reading
is displayed intermittently. Change the transmitter battery!
LOb
E
Pairing has not been conducted between the dive computer and
the transmitter before the start of the dive. No cylinder data avail-
able.
OFF
43