1.

Ensure that the transmitter is properly attached to the regulator’s HP port and
that the regulator is properly attached to the cylinder.

2.

Ensure that the Suunto Vyper Air is turned on, and that the wireless integration
is enabled in the Suunto Vyper Air settings (HP set ON, refer to Section 5.7.11.
Setting the HP code
).
The Vyper Air should display “cd:--” in the lower left corner
of the alternative display.

3.

Slowly open the cylinder valve fully and pressurize the system. The transmitter
starts transmitting when the pressure exceeds 15 bar/300 psi.

4.

Take the Suunto Vyper Air unit close to the transmitter. The unit will then quickly
display the selected code number and then start displaying the transmitted cylinder
pressure. The wireless transmitter indicator (flash symbol) is displayed every time
the Suunto Vyper Air receives a valid signal.

WARNING

If there are several divers using Suunto with wireless transmission,
always ensure that each diver is using a different code before
starting the dive.

Reset the transmitter's code manually, see Section 5.7.11. Setting the HP code.
After this, the transmitter selects a new code. The Suunto Vyper Air must be in “cd:--
“ mode to pair on the new code. This procedure can be used if, for example, your dive
buddy has the same code and you need to change it.

NOTE

In order to save battery energy, the transmitter enters power
saving mode with slower data transmission rate if the tank pres-
sure remains unchanged for more than five (5) minutes. The
transmitter continues transmitting with the saved code when any
pressure change is measured.