Alarm reason

Alarm type

Cylinder pressure reaches 50 bar/725 psi. The cylinder
pressure display will start to blink.

Three beeps with a three
second interval

Cylinder pressure reaches the selected alarm pres-
sure.

Calculated remaining air time reaches zero.

No-decompression dive turns into a decompression
stop dive. An arrow pointing upwards and the blinking
ascent warning ASC TIME will appear.

Three beeps with a three
second interval and activated
backlight

Maximum allowed ascent rate, 10 m per min/33 ft per
min, is exceeded. Ascent rate bar graph blinks and
STOP warning appears.

Continuous beeps and activ-
ated backlight

Decompression ceiling depth is exceeded. An error
warning Er and a downward pointing arrow appear.
You should immediately descend to, or below, the
ceiling. The instrument will otherwise enter a perman-
ent Error mode within three minutes, indicated by a
permanent Er.

You can set alarms for maximum depth, dive time and tank pressure. For more inform-
ation, refer to Section 5.7. DIVE mode settings and Section 4.1. TIME mode settings.