beautypg.com

SUUNTO EON STEEL User Manual

Page 9

background image

WARNING: DO NOT EXPOSE ANY PART OF YOUR DIVE

COMPUTER TO ANY GAS MIX CONTAINING MORE THAN 40%

OXYGEN! Enriched air with greater oxygen content presents a risk

of fire or explosion and serious injury or death.

WARNING: THE DIVE COMPUTER WILL NOT ACCEPT

FRACTIONAL PERCENTAGE VALUES OF OXYGEN CONCENTRATION.

DO NOT ROUND UP FRACTIONAL PERCENTAGES! For example,

31.8% oxygen should be entered as 31%. Rounding up will cause

nitrogen percentages to be understated and will affect

decompression calculations. If there is a desire to adjust the

computer to provide more conservative calculations, use the

personal adjustment feature to affect decompression calculations or

reduce the PO2 setting to affect oxygen exposure according to the

entered O2% and PO2 values. As a safety precaution, the oxygen

calculations in the dive computer are made with an oxygen

percentage of 1% + set O2%.

WARNING: SET THE CORRECT ALTITUDE SETTING! When diving

at altitudes greater than 300 m/1000 ft, the altitude setting must be

correctly selected in order for the computer to calculate the

decompression status. The dive computer is not intended for use at

altitudes greater than 3000 m/10000 ft. Failure to select the correct

altitude setting or diving above the maximum altitude limit will

result in erroneous dive and planning data.

9