Specifications, Components, 5 components – SeaLand JW Series VacuFlush Vacuum Generator User Manual
Page 4: 4 specifications, 2 electrical specifications 4.3 dimensions, 1 materials, Sealand jw vacuum generator specifications
4
5 Components
(fig . 1 , page 2)
Ref.
Description
A
Inlet fitting
B
Outlet fitting
C
Vacuum tank
1
Refer to complete parts list (packed separately) for additional information .
4.2
Electrical specifications
4.3
Dimensions
(fig . 2 , page 2)
Ref.
Dimension
A
20 .125 in . / 511 mm
B
14 in . / 356 mm
C
9 .125 in . / 232 mm
2
4 Specifications
4.1 Materials
Pump body: glass-filled polypropylene
Pump bellows: engineered PP/PE resin
Duckbill valves: EPDM
Vacuum tank and fittings: glass-filled
polypropylene
SeaLand JW Vacuum Generator
Specifications
Model
Voltage (Dc)
Power Draw
(amp average)
Fuse/
breaker
Flow
(GPM/LPM)
Wire
size
Weight
(kg/lbs.)
VG4-12
12
6
10
5 .1 / 19 .3
follow local
codes*
15 .1 / 6 .9
VG4-24
24
3
5
5 .1 / 19 .3
follow local
codes*
15 .1 / 6 .9
* For marine applications follow ABYC wiring recommendations .
Specifications subject to change without notice .
Ref.
Description
D
Vacuuum switch
E
Vacuum pump motor
F
Vacuum pump body
CAUTION! ELECTRICAL HAZARD
DO NOT cONNEcT JW SERIES VAcuuM GENERATOR DIREcTLy TO STANDARD
RESIDENTIAL WIRING SySTEM. JW series vacuum generator operates on 12 V DC
or 24 V DC through a 10-amp or 5-amp circuit (see Section 4 .2 for electrical specifica-
tions) . For residential use, this product must be connected to a minimum 12-amp power
converter with 12 V DC electrical output .