8

0.75 in./

19 mm

SEACOCK

1 in./ 25 mm

or 1.5 in./38 mm

SEACOCK

0.75 in./

19 mm

SEACOCK

1 in./ 25 mm

or 1.5 in./38 mm

SEACOCK

MAKE LOOP

12 in./305 mm

ABOVE FLOOR

MACERATOR

TOILET

Installation

5

Installation

5.1

Above water line system layouts

Note

Determine whether the water supply to the toilet will be fresh water or sea water, above or below the
vessel’s water line, and then follow the appropriate instructions for the installation.

5

6

VENT

FITTING

0.75 in./ 19 mm ID

SEA WATER LINE

0.75 in./ 19 mm ID

SEA WATER LINE

0.5 in./

13 mm ID

FRESH

WATER

LINE

0.5 in./

13 mm ID

FRESH

WATER

LINE

FROM

FRESH

WATER

SUPPLY

FROM

FRESH

WATER

SUPPLY

CHECK VALVE is needed

to ensure sea water pump

stays primed between uses

CHECK VALVE is needed

to ensure sea water pump

stays primed between uses

Add vented loop here

if holding tank is

below water line.*

1 in./ 25 mm

or 1.5 in./38 mm ID
SANITATION HOSE

VENT

FILTER

HOLDING TANK

(cut-away view)

DISCHARGE

PUMP

DECK

DISCHARGE

WATER LINE

WATER LINE

Toilet with direct overboard
discharge

Toilet with
holding tank
discharge

Caution! Hazard of Flooding
All vented loops should be installed a minimum of 8 in./20 cm above water line at full heel.

*