SeaLand W Series Motor Conversion User Manual
For vacuum pumps and discharge pumps

1. Flush a large amount of soapy water through pump.
2. Turn off electric power to pump and disconnect motor leads.
3. Remove pump cover (two screws).
4. Remove 3/4-inch hex head shoulder bolt from motor
eccentric (through upper arm of bellows assembly).
5. Remove four 5/16-inch hex head screws that secure the motor
to the pump.
6. Remove eight 5/16-inch head screws that secure the top
closure to the pump body. Lift off top closure.
7. Lift bellows assembly from pump body by inserting screwdriver
through upper arm of bellows and pulling up on both ends of
screwdriver. The half clamps will come out of pump body with
bellows assembly.
8. Remove large rubber seal from top of pump body.
Installing New Bellows and Motor
1. Insert new large rubber seal into groove on top of pump body,
making sure there is no debris in groove.
2. Lubricate new small rubber seal with liquid soap or silicone
grease. Place small rubber seal on inside ledge at top of new
bellows assembly.
3. Lubricate inside of plastic bushing (in upper arm of new
bellows assembly) with silicone grease. Install new
shoulder bolt through plastic bushing in bellows
assembly.
4. Place half clamps around neck of bellows assembly.
5. Insert bellows assembly and half clamps into pump body. Be
sure upper arm of bellows is in line with inlet and outlet fittings
of pump. Press bellows and half clamps down into pump body
(it may be necessary to tap on clamps with a hammer to get
clamps fully seated).
6. Align threaded hole in motor eccentric with 3/4-inch hex head shoulder bolt in bellows assembly. Install and
tighten shoulder bolt.
7. Reassemble the pump and motor.
8. Reinstall the pump cover.
9. Connect motor leads to incoming power source and turn on electrical power.
If small rubber seal and large rubber seal are damaged, replace with
SeaLand Vacuum/Discharge Pump Repair Kit 385310151.
W Series Motor Conversion Kit
Installation Instructions
For Vacuum Pumps and
Discharge Pumps
Tools Required
• 5/16-inch socket wrench
• 3/4-inch open or box-end wrench
• Small phillips-head screwdriver
Removing Old Motor and Bellows
Dometic Corporation
Sanitation Division
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611-0038 USA
330-496-3211
1-800-321-9886 • Fax: 330-496-3097
® Registered; ™ Trademark of Dometic Corporation
© Dometic Corporation
600344821 1/09
PUMP COVER
MOTOR
ECCENTRIC
MOTOR
BRACKET
TOP CLOSURE
PLASTIC
BUSHING
SHOULDER
BOLT
BELLOWS
ASSEMBLY
PUMP
BODY
HALF CLAMPS
(2)
SMALL RUBBER SEAL
LARGE
RUBBER SEAL
WARNING – ELECTRICAL SYSTEM.
Turn off electrical power before servicing.
WARNING – MOTOR MAY START AUTOMATICALLY.