SeaLand TankMaster 6 User Manual
Page 4

4
TABLE OF CONTENTS
Item Number
Description
313806012
TM6-12 (12 VDC) TankMaster 6
313806024
TM6-24 (24 VDC) TankMaster 6
317301200
T-12 (12 VDC) Discharge Pump
317302400
T-12 (24 VDC) Discharge Pump
600343497
Seacock Interlock Switch for Congraco 1-1/2-inch Seacock Only
600343675
Seacock Interlock Switch for Groco 1-1/2-inch Seacock Only
307230272
Universal Flange (3-inch NPT) with gasket and stainless streel hardware
SPECIFICATIONS
Product Name: TankMaster
6 Automatic Discharge Pump Controller
Electrical:
Output Current Capability
Maximum Relay Rating for 12 or 24 VDC Discharge Pump: 40 amps inrush, 30 amps continuous.
Float Switch Rating: 20 watts with resistive load.
Current Consumption
Current ratings include the Wema gauge only; they do not include any other accessories such as a
discharge pump and optional indicator lights.
Maximum (full level)
Minimum (empty level)
12 VDC
24 VDC
12 VDC
24 VDC
Gauge Readout Only:
0.082 amps
0.041 amps
0.049 amps
0.025 amps
Manual Mode:
0.190 amps
0.095 amps
0.164 amps
0.082 amps
Automatic Mode:
0.410 amps
0.205 amps
0.049 amps
0.025 amps
Maximum Tank Pressure: 25 PSI
Materials:
Control Module Housing
Tank Mounted Float Switch Cap
Float Switch Body
O-Rings
Adjustable Stems
Compression Nut
-----------------------------------
-----------------------------------
-----------------------------------
-----------------------------------
-----------------------------------
-----------------------------------
ABS
PVC
Polypropylene
Nitrile
Cross Linked Polypropylene
Glass Reinforced Polypropylene