2general safety instructions, 3intended use, 4components and functions – SeaLand DTM01C Tank Monitor User Manual
Page 3: 5specifications

3
2
General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
• Faulty assembly or connection
• Damage to the unit from mechanical influences, misuse or abuse
• Alterations to the unit without express written permission from the manufacturer
• Use for purposes other than those described in the operating manual
Dometic Tank Monitor
General safety instructions
3
Intended use
(fig . , page 2)
DTM01C Tank Monitor panel indicates when a wastewater holding tank is almost full . This monitor helps
prevent damage to the boat that can happen because of accidental overfilling of the holding tank .
Caution!
Operator must know local regulations for emptying a holding tank .
4
Components and Functions
Probe Cap with Float Switch
The probe cap installs into a threaded 3-inch (76 mm) FPT opening on the top of a Dometic
®
holding
tank or other holding tank equipped with such an opening . As the level of holding tank contents
rises, the float switch inside the tank is pushed upward and activates the “Full Tank” light on the
indicator panel .
Indicator Panel
The indicator panel has a single light which is activated by the float switch inside the holding tank .
When the “Full Tank” light is activated, the operation of any plumbing fixture connected to the
holding tank should stop until the tank is emptied .
1
Items in fig. , page 2
Description
1
Probe cap with float switch
2
Indicator panel
3
#6 fasteners
2
5
Specifications
5.1
Materials
Average current consumption: 0 .016 amps at 12 V DC . Requires 0 .5-amp fuse .
5.2
Electrical Current Draw
ISO8846; EMC Directive 2004/108/EC
5.3
Approvals
Panel frame:
ABS
Panel:
Polyester
Probe cap:
PVC
Float switch:
Nitrile rubber ebonite