4 components, 5 specifications – SeaLand DTD01 Discharge Pump Control User Manual
Page 6
![background image](/manuals/710632/6/background.png)
6
Dometic Tank Discharge Control
Intended use
System Voltage
Pump Off (amp)
Pump On (amp)
12 V DC
0
0 .16
24 V DC
0
0 .095
4 Components
Items in fig.
1 page 2
Description
Item Number (Europe / North America)
1
Replacement key
860003853110362 / 385311036
2
Switch assembly
860003853116104 / 385311610
3
Panel cover
860003853116112 / 385311611
4
#6 fastener
860003853116120 / 385311612
5
Mounting frame
860003853116138 / 385311613
6
Circuit assembly
860003853116146 / 385311614 – 12 V DC
860003853116153 / 385311615 – 24 V DC
7
Circuit assembly housing
860003853116161 / 385311616
1
5 Specifications
5.1 Materials
3.3 Features
Secure discharge pump control. Key-operated switch provides convenient means to secure
discharge pump operation without use of padlocks or other mechanical fasteners .
Helps prevent pump burn-out. Activated panel light indicates when discharge pump is operating.
Reminds operator to shut off pump when tank discharge is complete .
Automatic pump shut-off with DTM04 tank monitor system. Discharge pump stops when tank level
drops below “Empty” level probe (fig. 6 4, page 4).
Simplifies plumbing system. Eliminates wye valves, seacocks and vented loops of multiple
toilet systems .
5.2
Electrical Current Draw (panel only)
Panel frame and mounting frame: ABS Panel surface: Polycarbonate resin
Circuit assembly housing: High-density polyethylene
6
Specifications subject to change without notice .
Caution!
Operator must know local regulations for emptying a holding tank.