SeaLand DNF Status Panel

Intended use

in the process of building vacuum to the proper level for the next flush. When the red light shuts off, the
toilet system is ready for the next flush.

3.3 Features

Continuous vacuum level monitoring. When connected to a VacuFlush system, the panel indicates
when VacuFlush toilet is not ready to flush due to low vacuum.
12 or 24 V DC operation.

4

Components

(fig.

1

, p. 2)

Ref

Description

1

DNF panel cover

2

Mounting frame

3

#6 fastener

5 Specifications

5.1 Materials

Panel cover frame and mounting frame: ABS
Panel cover surface: Polycarbonate resin

5.2 Electrical

Current and wattage per indicator light

12 V DC

24 V DC

Amps

0.019

0.019

Watts

0.23

0.46

5.3 Dimensions

(fig.

2

, p. 2)

Ref.

Dimension

A

2 in. / 51 mm

B

3.25 in. / 83 mm

C

2 in. / 51 mm clearance behind wall

D

0.38 in. / 10 mm

5.4 Approvals

ISO 8846; EMC Directive 2004/108/EC