Form P-X/XE/RX/RXE, P/N 264000, Page 5

A B C

Code 15 - Remote Electronic Ductstat

Code 14 - Ductstat

Sensor Holder,

#TE6001-1, P/N 115850

Sheetmetal

Retaining

Plate,

P/N 7727

Element Bracket

P/N 100260*

Cabinet

Leg

Gasket,

P/N 7726

Capillary

*Element bracket

P/N 100260 is for

CODE 11, P/N 41700,

manufactured by

Honeywell. If using a

CODE 11, P/N 41700,

manufactured by

Essex Corporation,

the element bracket

P/N is 104156.

(Entrance

in ductwork)

Code 13 - Bracket, P/N 104156

(used with Essex brand P/N 41700);

P/N 100260 (used with Honeywell

brand P/N 41700 - see Code 11)

Gasket, P/N 7726

Retaining Plate, P/N 7727

Ductstat Sensor,

#SET A99BC-25C,

P/N 115851

(Used in Options AG15-

AG20 with Code 312)

A = Ductstat Temperature Selector Module, J/C A350AA-

1C,

P/N 115848 (used in Options AG 15-20)

B = Stage Adder Module, J/C S350AA-1C, P/N 115849

(used in Options AG 15-20)

C = Digital Temperature Display Module, J/C D350AA-1C,

P/N 115852 (used in Options AG 16, 18, and 20)

Code 16 - P/N 131450,

ECO Device, 306°F

(on match lit units -

prior to 10/2003)

Mounting Plate - X and

XE Series, P/N 82633

Code 18 - Time

Delay Relay, T&B

Agastat TM1ULA,

P/N 89661

Used in

freezestat

circuit

Code 19 - Heat Shields

U.S.,

P/N 10188

Canada,

P/N 63818

Code 20- Dirty Filter

Switch, P/N 105507,

TriDelta AP4434

Contacts close @.17 to

5.0" w.c. ± .06

Code 21 -

Fuse

Holder,

P/N 38635

Fuses

2.5 Amps,

P/N 61542

5 Amp,

P/N 90335

8 Amp,

P/N 38636

Code 23 - Freezestat, High

Ambient Lmit, Outside Air and

Return Air Control, P/N 126170,

J/C A19AAF-12C, 25-225°F

(replaces P/N 16108)

Code 22 - Blower Airflow

Switch, P/N 112107, Tridelta

FP6605, N.O. non-adjustable

setpoint .175" w.c.

(Air proving

switch,

Option

BW1)

Bulb Bracket,

P/N 100260

Grommet Clamp,

P/N 131993

Cable Clamp,

P/N 132065

Code 17 - Summer/Winter Switch (used

in Options BF4 and CH1)

P/N 3745 (6 Amp) Sizes 75 - 200

P/N 8336 (10 Amp)

Sizes 225 - 400

Code 24 -

Control and

Damper

Transformer

P/N 103054, 225/24/20VA,

Basler #BE121625-WAR
P/N 103055, 115/24/40VA,

Basler BE141650-WAA
P/N 103497,

208/230/24/40VA, Basler

#BE2153900
P/N 103498, 460/24/40VA,

Basler #BE23975001

Code 25 - KVA

Transformer(Primary

as listed; 120V

Secondary)

KVA 200/208 220/240/440/480

277

575

.25

19807

11279

113556

.50 19808*

11100

14993*

.75 24453*

11217

14994*

1.0 24454*

16065

14995*

1.5 24455*

24392*

14996*

2.0 24456*

26628*

14997*

3.0 24465*

26630*

14998*

5.0 24466*

26631*

15003*

*Special order

Code 26 - Vent Damper (in

Option AV7)

P/N

Description

234007

Vent Damper, 6"

234008

Vent Damper, 7"

234009

Vent Damper, 8"

234010

Vent Damper, 10"

234011

Vent Damper, 12"

This manual is related to the following products: