beautypg.com

Heater serial no. prefix and suffix codes, Model no. decoding, Heater model no. suffix codes – Reznor Valves Parts Manuals User Manual

Page 5

background image

Form P-VALVES, P/N 263995R4, Page 5

Heater Model No. SUFFIX Codes

Heater Serial No.

PREFIX and SUFFIX

Codes

Serial Number PREFIX Codes and Definitions:

Code

Explanation

E

= E3 (409) stainless steel heat exchanger

S

= 316 or 321 stainless steel heat exchanger

Serial Number SUFFIX Codes and Definitions:

Code

Explanation

B

= Baso pilot (indicates Baso pilot in place of General Controls pilot)

CA

= Constant air volume

EE

= Energy efficient motor

FD

= Fan duct furnace (spotter)

HV

= High throw fan assembly

MP1

= Modulating gas control with 20%-100% firing rate (AG39)

For a list of components of

Maxitrol electronic modulation

systems used on Model Series X,

SC, RX, RPV, RG, RP, and EEDU

indirect-fired equipment, see pag-

es 25-27. For list of components

of Maxitrol electronic modulation

systems used on Model Series

ADF, DV, and RDFdirect-fired

equipment, see pages 27-28.

MP2

= Modulating gas control with 20%-100% firing rate with signal conditioner for DDC (AG40)

MP3

= Modulating gas control 20-100% firing rate on 1st furnace; 2-stage on 2nd (AG41)

MP4

= Modulating gas control 20-100% on 1st furnace; 2-stage on 2nd - w/signal conditioner for DDC (AG42)

MP5

= 1-stage on 1st furnace; 2-stage on 2nd furnace (AG43)

MP6

= 1-stage on 1st furnace; 2-stage on 2nd furnace - with signal conditioner for DDC (AG44)

MV1

= Maxitrol 20AH Electronic Modulation (50-100%) System (AG7 for single furnace)

MV2

= Maxitrol 30AH Electronic Modulation (50-100%) System (AG7 for multiple furnaces)

MV3

= Maxitrol 21H Electronic Modulation (50-100%) System (AG8 for single furnace)

MV4

= Maxitrol 21HR Electronic Modulation (50-100%) System (AG9 for single furnace)

MV5

= Maxitrol 31H Electronic Modulation (50-100%) System (AG8 for multiple furnaces)

MV6

= Maxitrol 31HR Electronic Modulation (50-100%) System (AG9 for multiple furnaces)

MV7

= Maxitrol 14 Electronic Modulation System (AG30 and AG31)

MV8

= Maxitrol 14A and 14B Electronic Modulation Systems (AG32 and AG35)

MV9

= Maxitrol 44 Electronic Modulation System (AG33)

MVA = Maxitrol Electronic Modulation (50-100%) System w/Signal Conditioner for DDC on Indirect-Fired Equipment (AG21)
MVB = Maxitrol 94 Electronic Modulation System for Paint Booth for Direct-Fired Equipment (AG36)

(Reference NOTE: For PREEVA

indirect-fired models, see Form

P-PREEVA for modulation control

components.)

MVC = Maxitrol Electronic Modulation System with Signal Conditioner for DDC on Direct-Fired Equipment (AG37)
MVD

= Maxitrol DFM14E Digital Control System (AG47) (Direct-fired RDF or DV)

MVE

= Maxitrol DFM 44E Digital Control System (AG48) (Direct-fired RDF or DV)

MVF

= Maxitrol DFM 44E Digital Control System with Remote Sensor (AG51) (RDF or DV)

RA

= Recirculation air

TE

= Totally enclosed motor

TS

= Two speed motor

VA

= Variable air volume

X

= Manufactured in Mexico

In addition to the five elements found in every serial number, the heater serial number may be

coded with prefixes and suffixes that further identify optional equipment or capabilities applicable

to that particular unit. All prefix and suffix codes are listed below. See pages 3-4 for explanation

of the basic elements of a serial number.

SUFFIX

Code

Explanation

-2

= Two stage heating/MUA control

-2L

= Two stage control (heating/MUA) with 33% low fire and constant thermal efficiency (AG60, AG61, AG62)

-C

= Unit with a C.G.A. rating plate

-CV

= Common vent

-D2

= Digital control, space temperature, 2-stage heating/3-stage cooling (DG1)

-D2J

= Digital control, electronic modulation heating/3-stage cooling (DG2)

-DM

= Digital control, discharge temperature (makeup air), 2-stage heating/3-stage cooling (DG5)

-DMJ

= Digital control, discharge temperature (makeup air), electronic modulation heating/3-stage cooling (DG6)

-E

= Intermittent spark pilot (Applies to Models F, B, X, XE, XL, XLB that have a standard match lit pilot; models

that have a standard spark pilot do not have this code.)

-H

= Orificed for high altitude

-IL

= Manifold arrangement and remote console for Illinois School Code

* -J

= Makeup air (code appears on blower cabinet plate only)

* -JR

= Makeup air with evaporative cooling (code appears on blower cabinet plate only)

-LN

= Low noise

-M

= Mechanical modulation

-MB

= Mechanical modulation with full fire bypass

-MP

= Electronic modulation (20-100% firing rate)

-MV

= Electronic modulation (50-100% firing rate)

-R

= Evaporative cooling

-S

= Stainless steel heat exchanger

-W

= Wide heater cabinet on Models RX75 and 100 Series 5 and 6

* -Y

= High fire lightoff

-Z

= Equipped with “Z” baffle for 4-foot stack extension

The Model No. may or may

not include suffix code(s) that

further identify the heater. See

the listing in the table for their

identification.

Model No. Decoding

HX

100

8

S

Model Size Series Suffix

*Effective 12/96, Codes J, JR,

and Y are no longer used.