beautypg.com

Reznor Valves Parts Manuals User Manual

Page 15

background image

Form P-VALVES, P/N 263995R4, Page 15

(continued)

Serial No.

Code

Original Valve on Heater

Valve

Mfr

1

Pipe

Size

P/N

2

Functional Replacement

Code

P/N

O3&P3

33

(Two

Valves)

AG14 Mechanical modulation 90-130°F, Code N2, w/bypass, Code M6, Sizes 300-400 and ADF/ADFH Nat & LP

36D19-403 Natural

W/R

3/4x3/4 100322-N/A

34

36C68-452 Natural, single stage

W/R

3/4

96309(M6)-N/A

Kit P/N 222037

O4&P4

33

(Two

Valves)

AG14 Mechanical modulation 90-130°F, Code N4, with bypass, Code M7, for Sizes 75-200

36D19-406 Propane

W/R

3/4x3/4 100324-N/A

3

VR8204M1018 Propane, single stage

M/H

1/2

96310(M7)

O5&P5

33

(Two

Valves)

AG14 Mechanical modulation 90-130°F, Code N4, with bypass, Code M8, for Sizes 225-400

36D19-406 Propane

W/R

3/4x3/4 100324-N/A

3

36C68-325 Propane, single stage

W/R

1/2x3/4 96311(M8)-N/A

Kit P/N 221634

P6 (Two

Valves)

Mechanical modulation 50-90°F, Code N1, with bypass, Code Q3, for Sizes 175-250

36D19-402 Natural

W/R

3/4x3/4 100321(N1)-N/A

34

VR8304M2816 Natural, single stage

M/H

1/2

121599(Q3)

P7 (Two

Valves)

Mechanical modulation 90-130°F, Code N2, with bypass, Code Q3, for Sizes 175-250

36D19-403 Natural

W/R

3/4x3/4 100322-N/A

3

VR8304M2816 Natural, single stage

M/H

1/2

121599(Q3)

P8

36C40-408 2-Stage, Natural (std pilot)

W/R

3/4

115351

P9

36C41-408 2-Stage, Propane (std pilot)

W/R

3/4

115352

Q2

VR8304M2808 Natural, single stage

M/H

1/2

121598

Q3

VR8304M2816 Natural, single stage

M/H

1/2

121599

Q4

VR8304H3802 Propane, single stage

M/H

1/2x3/4

121600

Q5 (Two

Valves)

Mechanical modulation 50-90°F, Code N1, with bypass, Code J8, for Sizes 300-400

36D19-402 Natural

W/R

3/4x3/4 100321(N1)-N/A

34

36C68-441 Natural, single stage

W/R

3/4

89397(J8)-N/A

9A

221525

Q6 (Two

Valves)

Mechanical modulation 90-130°F, Code N2, with bypass, Code J8, for Sizes 300-400
36D19-403 Natural

W/R

3/4x3/4 100322-N/A

3

36C68-441 Natural, single stage

W/R

3/4

89397(J8)-N/A

9A

221526

Q7 (Two

Valves)

Mechanical modulation 50-90°F, Code N1, with bypass, Code Q2, for Sizes 75-250

36D19-402 Natural

W/R

3/4x3/4 100321(N1)-N/A

34

VR8304M2808 Natural, single stage

M/H

1/2

121598 (Q2)

Q8 (Two

Valves)

Mechanical modulation 90-130

o

F, Code N2, with bypass, Code Q2, for Sizes 75-250

36D19-403 Natural

W/R

3/4x3/4 100322-N/A

3

VR8304M2808 Natural, single stage

M/H

1/2

121598 (Q2)

Q9 (Two

Valves)

Mechanical modulation 50-90

o

F, Code N3, with bypass, Code Q4, for Sizes 75-200

36D19-405 Propane

W/R

3/4x3/4 100323(N3)-N/A

34

VR8304H3802 Propane, single stage

M/H

1/2x3/4

121600(Q4)

R1 (Two

Valves)

Mechanical modulation 90-130

o

F, Code N4, with bypass, Code Q4, for Sizes 225-400

36D19-406 Propane

W/R

3/4x3/4 100324-N/A

3

VR8304H3802 Propane, single stage

M/H

1/2x3/4

121600(Q4)

R2

5

K3A651SF Natural & Propane

G/C

3/4

123604

R3

5

K3A561-U Natural & Propane

ASCO

1

123603

R4

5

K3A671SF Natural & Propane

G/C

1-1/4

123605

R5

V4600A1023 Nat or V4600A1031 Nat/Pro

M/H

1/2

113766

R6

V4400A10093

M/H

1/2

113767

35

R7

3B0-341-A04 or 3F1241A04 Natural, 50-100°F, Mod

R

3/4

131453

35

R8

5N7-341-A04 or 5R9241A04 Natural, 50-100°F, Mod

R

1

131455

35

R9

3B0-342-A05 or 3F1242A05 Propane, 50-100°F, Mod R

3/4

131454

35

S1

5N7-342-A05 or 5R9242A05 Propane, 50-100°F, Mod R

1

131456

S2 (Two

Valves)

3B0-341-A04 or 3F1241A04 Natural, 50-100°F, Mod

R

3/4

131453(R7)

36C68-325, Propane, single stage

W/R

1/2X3/4 96311(M8)-N/A

Kit P/N 221634

S3 (Two

Valves)

5N7-341-A04 or 5R9241A04 Natural, 50-100°F, Mod

R

1

131455(R8)

36C68-442, Propane, single stage

W/R

3/4

89398(K1)-N/A

1B

221526

S4 (Two

Valves)

3B0-342-A05 or 3F1242A05 Propane, 50-100°F, Mod

R

3/4

131454(R9)

36C68-325, Propane, single stage

W/R

1/2x3/4 96311(M8)-N/A

Kit P/N 221634

S5 (Two

Valves)

5N7-342-A05 or 5R9242A05 Propane, 50-100°F, Mod R

1

131456(S1)

36C68-442 Propane, single stage

W/R

3/4

89398(K1)-N/A

1B

221526

S6 (Three

Valves)

Mechanical modulation 50-100°F, with bypass, Code Q2, for Sizes 75-225

3B0-341-A04 or 3F1241A04 Natural, 50-100°F

R

3/4

131453(R7)

36C68-325, Pro, single stage

W/R

1/2x3/4 96311(M8)-N/A

Kit P/N 221634

VR8304M2808 Natural, single stage

M/H

1/2

121598(Q2)

S7 (Three

Valves)

Mechanical modulation 50-100°F, with bypass, Code J8, for Sizes 250-350

3B0-341-A04 or 3F1241A04 Natural, 50-100°F

R

3/4

131453(R7)

36C68-442, Pro, single stage

W/R

3/4

89398(K1)-N/A

1B

221526

36C68-441 Natural, single stage

W/R

3/4

89397(J8)-N/A

9A

221525

T

ype of Valve Originally Supplied (cont'd) -- See Serial No. Decoding on pages 3-4.

A dash (-) in the serial number means that no electric valve was furnished. All valves are 24 volt unless noted otherwise.