Reznor Carryover Lighter Tube Parts Manuals User Manual
Description/application, Installation instructions, Caution: hold burner rack firmly and pull slowly

Form RZ-NA-P-X/XE-LTR-TUBE, Mfg #101147, Page 1
Installation Instructions for
Carryover Lighter Tube - Natural or
Propane Connection
Parts/Installation Form RZ-NA-P-X/XE-LTR-TUBE
Obsoletes RGM 704 (Version A)
APPLIES TO:
Model Series X, RX, XE, RXE, REB
Description/Application
These carryover kits are intended for installation on Model (H) (C) RX; (H) (C) X; (H) (C) RXE; (H) (C) REB, and (H) (C) XE that did not include
factory-installed lighter tube carryovers (units manufactured prior to 11/86).
Parts List (Lighter Tube Carryover Kits are listed by Size of Heater)
WARNING: All components of the gas supply system
must be leak tested prior to placing equipment into
service. Never test for leaks with an open flame.
Failure to comply could result in severe personal
injury or death. Use an approved leak-test solution
or soap solution to detect leaks.
Size
75/100
125
150/175 200/225 250/300
350
400
For NATURAL GAS Furnace - Kit P/N
92135
92136
92137
92138
92139
92140
92141
Components:
Lighter Tube Assembly
9899
9859
9821
9783
9747
9711
9520
Length (inches)
12-3/8
15-1/8
20-5/8
26-1/8
34-3/8
39-7/8
45-3/8
Drip Shield
15015
15014
15013
15012
15011
15010
14957
Carryover Orifice
9870
9870
9680
10370
10370
9792
9792
Drill Size
70
70
65
59
59
54
54
Aluminum Tube
93389
93389
93389
93389
93389
93389
93389
Brass Elbow
93388
93388
93388
93388
93388
93388
93388
Compression Fitting
9664
9664
9664
9664
9664
9664
9664
1/2" lg, #10 Sheetmetal Screw
11813
11813
11813
11813
11813
11813
11813
Quantity
6
6
6
6
6
6
6
For PROPANE GAS Furnace - Kit P/N
92142
92143
92144
92145
92146
92147
92148
Components:
Regulated Carryover Assembly
100712
100712
100712
100712
100712
100712
100712
Lighter Tube Assembly
9899
9859
9821
9783
9747
9711
9520
Length (inches)
12-3/8
15-1/8
20-5/8
26-1/8
34-3/8
39-7/8
45-3/8
Drip Shield
15015
15014
15013
15012
15011
15010
14957
Carryover Orifice
9870
9870
9680
9680
10370
9791
9791
Drill Size
70
70
65
65
59
56
56
1/2" lg, #10 Sheetmetal Screw
11813
11813
11813
11813
11813
11813
11813
Quantity
6
6
6
6
6
6
6
Drip
Shield
Lighter
Tube
Regulated
Carryover
Assembly for
Propane Gas
Installation Instructions
1.
Turn off the gas supply upstream of
the valve and turn off the electric.
2.
Mark the wires connected to the gas
valve and disconnect.
3.
Disconnect spark lead and flame sen-
sor from the ignition controller.
CAUTION: Hold burner rack firmly and pull slowly.
4
. Remove the burner rack.
a) Remove the heater side panel.
b) Uncouple the union in the gas supply to
permit removal of the burner rack.
c) Remove the sheetmetal screws in the top
corners of the burner rack and pull the
burner rack out of the unit.
5.
Follow the illustrated instructions on
pages 1-4 to install the Lighter Tube
Carryover Kit. Test for leaks. When the
installation is complete, reverse Instal-
lation Instruction Nos. 1-4 to re-
assemble the heater. Test for proper
and safe operation.
INSTALL LIGHTER TUBE - Steps 1-6 apply both natural gas and propane gas heaters.
1. Burner rack
without
lighter tube.
2. Back off screws that
attach the manifold
to the burner rack.
Remove top screws.
®