background image

2

Fit air inlet plate here
on top of orifice plate

.

VPS Models

Any unused components supplied with the fresh air

inlet conversion kits need to be disposed of

accordingly as not all parts supplied are required.


There are two different fresh air inlet plates, one has three
fixing holes and one has four fixing holes (see table).
Follow the relevant procedure for the type of fan fitted to
the appliance being converted.

Section 1 ………………………. VPS Three fixing fan.

Section 2 ………………………. VPS Four fixing fan.

Section 3 ………………………. VPT

Section 4 ………………………. VCS/VCT

VPS/VPT CONVERSION KIT PART NUMBER 270613

Part No.

Description

Quantity

270426

5mm dia x 10mm long screw

3

269916

4 hole fresh air inlet plate

1

269913

3 hole fresh air inlet plate

1

270422

Hose clamp 90-120mm

2

270462

Flexible hose 108mm dia x 350mm long

1

270688

Combustion air conversion manual

1

Fresh Air Inlet Plate Type

Size

60

80

100 125 150 170 200

VPS 3 Hole

*

*

*

*

*

*

VPS 4 Hole

*

VPT

Already fitted (kit inlet plates not needed)

VCS/VCT

Already fitted (no inlet plate in kit)

VCS/VCT CONVERSION KIT PART NUMBER 270614

Part No.

Description

Quantity

270435

5mm dia x 16mm long stainless steel screw

3

270423

Stainless steel hose clamp 90-120mm

2

270462

Flexible hose 108mm dia x 350mm long

1

270688

Combustion air conversion manual

1