beautypg.com

OmniSistem Sky Scan User Manual

Page 5

background image

Switch #3 On: (Walker)

Pattern5 Beam Type: A single beam that sweeps from left maximum to right maximum, the full legal limit
set by switch #9, in increasing sweep size which collapses slowly on the other side. It then reverse repeats
several times.

Pattern6 Beam Type: A single fan that opens from left maximum to right maximum, the full legal limit set by
switch #9, in increasing fan size which collapses slowly on the other side. It then reverse repeats several
times. This pattern requires switch #8 to be set ON to view it.

Switch #4 On: (Random)

Pattern7 Beam Type: A single beam that selects random targets over the full legal limit set by switch #9.
This one is timed for about 15 seconds before proceeding to next pattern.

Pattern8 Fan Type: A small fan that selects random targets over the full legal limit set by switch #9. This
one is timed for about 15 seconds before proceeding to next pattern.
This pattern requires switch #8 be set ON to view it.

Switch #5 On: (Random)

Pattern9 Beam Type: A single beam that sweeps from left maximum to right maximum and back using the
full legal limit set by switch #9, pausing briefly at random beam positions and then repeating several times.

PatternA Fan Type: A small fan that sweeps from left maximum to right maximum and back using the full
legal limit set by switch #9 , pausing briefly at random fan positions and then repeats several times.
This pattern requires switch #8 to be set ON to view it.

Switch #6 On: (Sound Level)

PatternB Beam Type: A single beam that sweeps from left maximum to right maximum only, using the full
legal limit set by switch #9, pausing briefly at each beam position determined by sound and then repeating
several times. This one has best repeatability for mirror bouncing.

PatternC Fan Type: A sweep from left maximum to right maximum only using the full legal limit set by
switch #9 , pausing briefly at each fan position
Set switch #10 to ON (up) and the unit will be in Full Automatic Mode.

Switch #9, if set ON, enables Wide Angle Scanning.
Switch #9, if set OFF, enables only %50 of the available Scan Angle.

Switch #8, if set ON, enables both beam patterns and fan patterns.
Switch #8, if set OFF, enables beam patterns only.

If switches #1 to #7 are ALL OFF then the unit defaults to Basic SkyScan Mode with switch #8 used to select
beam only or fan only scanning and switch #9 selecting the basic scan size.

If Switch #1 is ON then patterns 1 and 2 are enabled.
If Switch #2 is ON then patterns 3 and 4 are enabled.
If Switch #3 is ON then patterns 5 and 6 are enabled.
If Switch #4 is ON then patterns 7 and 8 are enabled.
If Switch #5 is ON then patterns 9 and A are enabled.
If Switch #6 is ON then patterns B and C are enabled.
If Switch #7 is ON then patterns D and E are enabled.