AVOID direct or collateral radiation from the laser.

NEVER point the aperture of this product in a way that the audience can be exposed to direct or

indirect laser light.

MAKE sure that all warning labels and product labels remain attached and in there proper place.


There are regulations that must be followed and adhered to when operating a laser system above
1mW.

ClassIIIa 1mw to 4.95mW

All laser radiation must remain 2.5 meters vertically above the floor.

ClassIIIb 5mW to 499mW to ClassIV >500mW

• All Laser Radiation must remain 3.0 meters vertically above the floor and 2.5 meters horizontally

away from human contact. This 2.5-meter rule applies to catwalks, balconies or other raised
surfaces.

• If the system is stand-alone with no operator present double the distances as stated above.

• In the event of a bounce mirror shift, beam turret failure, accidental exposure, scanner failure, or

other anomalous event that falls short of the CDRH guidelines IMMEDIATELY SHUT DOWN YOUR
LASER SYSTEM and do not operate it again until the problem has been remedied.

• Comply with all conditions of your variance. (Variance Regulated Products Only)

• Insure all beams and effects are terminated safely.

• Remember Safety should be your first priority.













For sales and service contact: PULSE
Laser Products Division
OmniSistem Lights and Effects
253-395-9500
253-395-9494 fax



LASER can only emit from this
device when attached to a laser
source. This unit contains no laser
source internally.