Setting all DMX Switches to OFF activates the Calibration Mode.
Note: If ALL switches are OFF then the Calibration Mode becomes active because
this is an illegal DMX address of 000.
Using a small tweaker flathead screw driver, turn the MIC adjustment down full counter clockwise. The
Beam position will now be centered ahead and no response to sound is expected.
Next play music in area typical of a live performance. Increasing the MIC sensitivity clockwise will cause the
beam to jump from center to positions further to it's right. If set too sensitive, the beam may stay at the far
right position during moderately loud music. Set the MIC for the most number of different beam positions
during a full performance.
The unit is now calibrated and ready for use.
On-Demand control requires use of DMX-512 or a PC serial interface connection.
Automatic is provided for those that don't have or don't need On-Demand control.
You can pick your favorite patterns and have them played through continuously.
Locate the 10 DMX Switches on the bottom of the control interface box.
They are numbered 1 to 10 from left to right.
If any of the pattern switches are ON then those patterns will be played. After a set time the next enabled
pattern in sequence will be played. Then, the whole process starts over again automatically.
Automatic Modes
Switch #1 On: (Walker)
Pattern1 Beam Type: Beam starts in center, then, steps open to full legal limit set by switch #9 and
collapses back to center again; then repeats.
Pattern2 Fan Type: Small fan starts in center then opens to full legal limit set by switch #9 and collapses
back to center again; then repeat. This pattern requires switch #8 to be set ON to view it.
Switch #2 On: (Walker)
Pattern3 Beam Type: A single beam that sweeps the full legal limit set by switch #9 and then repeats
several times.
Pattern4 Fan Type: A small fan that sweeps the full legal limit set by switch #9 and repeats several times.
This pattern requires switch #8 to be set ON to view it.
Calibration
Mode
–
Sky-Scan
3.0
Automatic Mode and Sound Activated – Sky-Scan