beautypg.com

9 hydraulic installation – NORAC UC5-BC-FT02 User Manual

Page 25

background image



22

9 Hydraulic Installation

Ensure all pressure has been bled from the system before disconnecting any lines or
fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings are being
supported by other means. You may wish to perform the hydraulic installation with the
wings in transport position, resting on the ground or with the tilt cylinders fully extended.

Component failure due to oil contamination is not covered under the NORAC UC5 system
warranty. It is recommended that a qualified technician perform the hydraulic installation.

9.1 Valve Assembly

1. On a clean surface remove the plastic plugs from the block.

2. Install the 6MB-6MJ (F04) fittings into the P and T ports. Tighten to 18 ft-lbs (24 Nm).

3. Insert the two orifices (F06) into the “B” ports with the notch facing outward.

4. Install the 6MB-6MJ (F04) fittings into the “B” ports. Tighten to 18 ft-lbs (24 Nm).

5. Install the 6MBP (F05) plugs into the “A” ports. Tighten to 18 ft-lbs (24 Nm).

Depending on the valve block part number, the A and B ports may be reversed. Ensure
that the orifices are oriented properly for the A and B ports or the system will not function
properly.

44963D 44933D