beautypg.com

NORAC UC5-BC-FT02 User Manual

Page 22

background image



19

4. Ensure the bracket is pushed over the connectors far enough to allow the clips to engage

behind the valve connectors.

Figure 17: Valve Module Bracket Installation

5. Connect the valve module CANbus to cable C01 from the control module. Route cable C02

from the other CANbus connector to the input module.

6. With the valve module securely mounted to the valve block, connect the valve cables (C10),

to the valve coils as illustrated in Figure 15 and Figure 18. Insert the 2-pin plugs (P01) into
the unused 2-pin connectors on the valve module.

7. Connect the temperature probe to the valve block using the supplied 3/8” x 1/2” hex bolt.

Figure 18: Valve Module - Valve Coil Connections

Tank Port

Pressure Port

Sense Port

Left Tilt Ports

Right Tilt Ports