NORAC UC5-BC-FT02 User Manual
Page 15
12
5.3 Wing Sensor Installation
1. The sensor bracket should be oriented forward (ahead of the boom).
2. Typically the best mounting location for the wing sensor brackets will be near the end of the
boom tips, approximately two feet (60cm) from the end.
3. Depending on the boom design, some breakaway sections will lift upwards as they break
back. If the sensor is mounted to this portion of the boom, the system will force the boom
downwards towards the ground as the boom folds backwards.
4. Mount the NORAC UC5 ultrasonic sensor into the sensor bracket.
A problem can arise if a sensor is not mounted correctly. It is possible for the sensor to
read off of the boom instead of the ground. This may only become apparent once the
controller is switched from soil to crop mode.
Also be careful that the sensor bracket does not collide with any other part of the boom
when the boom is folded to transport position. If possible, mount the sensor brackets while
the booms are folded to ensure they will not cause interference.
Figure 7: Sensor Reading Off Boom