5.4 Main Lift Sensor Installation

1. There are a variety of ways to mount the main lift bracket on most sprayers. The bracket

should position the sensor approximately in the center of the sprayer, forward of the boom.
An example of this mounting is illustrated in Figure 8.

2. Mount the ultrasonic sensor to the main lift bracket.

Figure 8: Example Mounting of the Main Lift Bracket

Avoid mounting the main lift sensor over or near a wheel-track. Measurements from the
wheel-track do not provide an accurate crop height and will cause measurement and
control error.

Ensure the bracket does not collide with any other part of the sprayer throughout the full
range of main lift motion.