beautypg.com

NORAC UC4+BC+SM1 User Manual

Page 13

background image

10

5. Sensor cables should run through the

mounting bracket tube and then behind
the member the bracket is mounted onto.
Cable-tie the connector in place. The
cable must not be allowed to hang below
the boom (Figure 6).

Figure 6 – Another Acceptable Mounting

Avoid mounting sensors in

locations where they may read
from parts of the boom as shown
in Figure 7.

Figure 7 - Poor Mounting

(Sensor reading off boom)

General mounting rules for UC4+
ultrasonic wing sensors:

a) In its lowest position, the sensor mouth

must be 9 inches or more from the
ground.

b) The bottom of the sensor must be at least

9 inches in front of the spray nozzles.

c) The bottom of the sensor must be at least

9 inches above the spray nozzles.

d) Ensure that there are no obstructions

within a 12-inch diameter circle
projected directly below the center of the
sensor.

e) The sensor should be approximately

vertical at normal operating heights.

Figure 8 - Sensor mounting guidlines

A

B

B

D

C

Ultrasonic
Acoustic Cone