9

4.3 W

ING

S

ENSOR

I

NSTALLATION

1. Assemble the Breakaway Sensor

Mounting Brackets (B11) as show in
Figure 4 and Figure 5.

Figure 4 – Breakaway Sensor Bracket

Exploded View

Figure 5 – Breakaway Sensor Mounting

Bracket Assembly

To assemble the breakaway sensor
bracket:

a) Assemble the bolt and nut into the

collar.

b) Grease the bottom edge of the collar

and the angled tube of the base.

c) Place the collar onto the angled tube

of the mounting base.

d) Install the spring between the collar

and the upper ring of the base.

e) Insert tube through assembly and

tighten the collar

2. Mount the sensor bracket onto the boom.

If possible, mount the sensor

brackets while the booms are in
their folded position to ensure that
they will not interfere with
anything when the boom is folded
for transport.

3. The mounting brackets can be installed

with the mounting base behind (Figure
8
) or in front of the tube (Figure 6).

It is advised to avoid mounting the

sensor bracket to a breakaway
portion of the boom because a
breakaway action can cause the
UC4+ system to force a boom close
to the ground. Please refer to the
UC4+ system warranty at the end
of the UC4+ Sprayer Boom
Control Operator’s Manual (M01)
for implications.

4. Mount the NORAC UC4+ ultrasonic

sensor (E02) into the sensor brackets.
The sensors should be oriented forward
(ahead) of the boom (see Figure 6 and
Figure 8)

When installing the UC4+ sensors

(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial
number on the right hand side
(Figure 9).