3 wing sensor installation – NORAC UC4+BC+SM1 User Manual
Page 12
9
4.3 W
ING
S
ENSOR
I
NSTALLATION
1. Assemble the Breakaway Sensor
Mounting Brackets (B11) as show in
Figure 4 and Figure 5.
Figure 4 – Breakaway Sensor Bracket
Exploded View
Figure 5 – Breakaway Sensor Mounting
Bracket Assembly
To assemble the breakaway sensor
bracket:
a) Assemble the bolt and nut into the
collar.
b) Grease the bottom edge of the collar
and the angled tube of the base.
c) Place the collar onto the angled tube
of the mounting base.
d) Install the spring between the collar
and the upper ring of the base.
e) Insert tube through assembly and
tighten the collar
2. Mount the sensor bracket onto the boom.
If possible, mount the sensor
brackets while the booms are in
their folded position to ensure that
they will not interfere with
anything when the boom is folded
for transport.
3. The mounting brackets can be installed
with the mounting base behind (Figure
8) or in front of the tube (Figure 6).
It is advised to avoid mounting the
sensor bracket to a breakaway
portion of the boom because a
breakaway action can cause the
UC4+ system to force a boom close
to the ground. Please refer to the
UC4+ system warranty at the end
of the UC4+ Sprayer Boom
Control Operator’s Manual (M01)
for implications.
4. Mount the NORAC UC4+ ultrasonic
sensor (E02) into the sensor brackets.
The sensors should be oriented forward
(ahead) of the boom (see Figure 6 and
Figure 8)
When installing the UC4+ sensors
(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial
number on the right hand side
(Figure 9).