6 hydraulic installation, 1 valve mounting – NORAC UC4+BC+NT3 User Manual
Page 19
16
4.6 H
YDRAULIC
I
NSTALLATION
If your sprayer has a valve block
with serial number 21.12732 or lower
then you must refer to Section 6 to
complete the hydraulic plumbing.
WARNING!
The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.
When changing the boom hydraulic
hoses leave the booms in
TRANSPORT POSITION.
IMPORTANT:
Component failure due to oil
contamination is not covered under
the UC4+ Spray Height Control
system warranty. It is recommended
that a qualified technician does the
hydraulic installation.
4.6.1 Valve Mounting
1. On a clean surface remove all plastic
plugs from the NORAC hydraulic Valve
(V01) (Figure 13).
Figure 13: NORAC Valve Block
2. Install the orifices (F08) into the "B"
ports as shown in Figure 14.
3. Install the 6MB-6MOR fittings (F02)
into the “B” ports and tighten to 18 ft-
lbs.
4. Install the 6MB-6MOR fittings (F02) in
the pressure (“P”) and tank (“T”) ports
and tighten to 18 ft-lbs.
5. Install the 6MBP plugs (F01) into the
“A” ports of the NORAC valve block
and tighten to 18 ft-lbs.
Figure 14: Valve Block Assembly
6. A valve mounting plate (B10) is
provided with 5/16” NC bolts, nuts and
washers. Mount the valve plate directly
under the spray nozzle valves.