beautypg.com

1 boom roll sensor mounting, 2 chassis roll sensor mounting, 3 temperature probe – NORAC UC4+BC+NT3 User Manual

Page 18

background image

15

Figure 11: Roll Sensor Mounting with Respect to Sprayer Orientation

4.5.1 Boom Roll Sensor Mounting

The boom roll sensor is the roll sensor
with the temperature probe attached to it
(E03). To mount the boom roll sensor,
refer to these guidelines.
a) The boom roll sensor must be attached

to the center part of the boom.

b) Use cable-ties to secure the bracket to

a square edge feature (square tube).

c) The AMP (circular) connector must be

pointing to the right hand wing (when
looking from the rear).

d) The ring terminal on the boom roll

sensor is a temperature probe and must
be attached to the side of the valve
block (Section 4.5.3).



4.5.2 Chassis Roll Sensor Mounting

The chassis roll sensor must be attached to

the chassis of the sprayer. To mount the
chassis roll sensor, refer to the following
guidelines.
a) The chassis roll sensor does not have a

temperature probe (E04).

b) Cable-tie the bracket to a square edge

(square tube).

c) The AMP (circular) connector must exit

towards the right hand wing (when
looking from the rear).

4.5.3 Temperature Probe

Fasten the temperature probe (E03) to
the UC4+ valve block using the included
3/8x1/2” bolt.

Figure 12: UC4+ Valve Block with

Temperature Probe Installed

The roll sensors must be

mounted with the Amp
connectors pointing to the
right.