beautypg.com

NORAC UC4+BC+JD6 User Manual

Page 26

background image

23

Figure 30: Cable Configurations: C01, C04 and C10

2. Connect the UC4 power cable (C10)

and sensor trunk cable (C01) to the
UC4 Control Panel (E01) in the sprayer
cab (Figure 30).

Ensure the UC4+ Control Panel’s

power is OFF for the remaining
installation. (Bottom of switch
pressed IN).

3. Plug the 3-pin connector on C10 into

the power bar inside the cab.

4. Route the free ends of C10 and C01

along the side of the cab post and under
the floor mat.

5. Plug in the 6-pin Tower on C10 to the

6-pin Shroud on the valve extension
cable (C04).

6. Route the free ends of C01 and C04

from inside the cab to the rear of the
sprayer in the vicinity of the sprayer
valve block.

C04 comes with one connector

unassembled. This will allow the

cable to be run through the hole
in the floor under the steering
column. To assemble this
connector (included), refer to the
drawing in Section 5.5. Take
extra care because the pins
require a special tool to remove
them if you make an error.

The hole in the floor may be

covered by a plate with screws

holding it in place, or a grommet
may be installed in the hole. They
can be reinstalled after the wiring
is complete. NORAC supplies a
grommet (Item M13) for the hole
if one does not exist. These
cables are to be run along the
sprayer frame with the JD
harness running to the rear of
the sprayer.