4 main lift sensor installation – NORAC UC4+BC+JD6 User Manual
Page 16
13
4.4 M
AIN
L
IFT
S
ENSOR
I
NSTALLATION
1. Assemble the main lift sensor bracket
(B11) as shown in Figure 13.
Figure 13: Main Lift Sensor Bracket
2. The bracket can then be mounted to
the lowest frame member on the center
section of the sprayer. The bracket
should be mounted so the sensor
mounting collar is in approximately the
center of the sprayer and ahead of the
boom (Figure 14 and Figure 15).
The sensor mounting collar must
not be behind the sprayer’s
wheel.
Figure 14: Main Lift Sensor Bracket
Mounting Position
3. Mount the sensor onto the sensor
mounting collar (Figure 14).
Figure 15: Main Lift Sensor Mounted
in the Correct Location
General Mounting Rules for UC4+
Ultrasonic Sensors:
a) In its lowest position, the sensor mouth
must be 9 inches or more from the
ground.
b) The bottom of the sensor must be at
least 9 inches in front of the spray
nozzles.
c) The bottom of the sensor must be at
least 9 inches above the spray nozzles.
d) Ensure that there are no obstructions
within a 12-inch diameter circle
projected directly below the center of
the sensor.
e) The sensor should be approximately
vertical at normal operating heights.
Bracket Tube
Sensor
Mounting Tab
Sensor Mounting
Collar
Bracket Base