Moog Crossbow VG700MB Series User Manual
Page 16
![background image](/manuals/699094/16/background.png)
VG700M User’s Manual
Page 10
Doc.# 7430-0280-01
Rev. F
Character(s) Sent
c
Response
C
Description
Changes measurement type to Scaled Mode.
DMU outputs measurements in scaled
engineering units.
Command
Angle Mode
Character(s) Sent
a
Response
A
Description
Changes measurement type to Angle (VG) Mode.
DMU calculates stabilized pitch and roll. Also
outputs sensor measurements in scaled
engineering units.
Command
Polled Mode
Character(s) Sent
P
Response
none
Description
Changes data output mode to Polled Mode.
DMU will output a single data packet when it
receives a "G" command.
Command
Continuous Mode
Character(s) Sent
C
Response
Data Packets
Description
Changes data output mode to Continuous Mode.
DMU will immediately start to output data
packets in continuous mode. Data rate will
depend on the measurement type the DMU is
implementing (Raw, Scaled, or Angle). Sending
a "G" will return DMU to Polled Mode.
Command
Request Data
Character(s) Sent
G
Response
Data Packet