beautypg.com

Level unit – Carrier Miracool 260L User Manual

Page 4

background image

4

LEVEL UNIT

To provide adequate condensate drainage and proper

door alignment and operation of unit, the unit cabinet

must be level. Leveling feet are factory installed.

Remove refrigeration system cartridge for easier

access to back feet.

„ TO REMOVE CARTRIDGE

1. After disconnecting the unit from the power

supply, remove the grille retaining screw located

in the upper-most part of the grille. (See Figure 1.)

2. Lift the grille up and away from the unit.
3. Unplug the power supply and lighting supply

cords located in the front of the cartridge

(Figure 2).

4. Using a pair of wire cutters, cut wire tie that

secures lifting rods at center of front base rail.

(See Figure 2.)

5. Take hold of the end of each lifting rod and rotate

each approximately 90-degrees upward so that

they are nominally vertical (Figure 3.) The car-

tridge should be disengaged from the cabinet and

resting on the base of the cabinet assembly. Han-

dling holes are located on either side of the car-

tridge near the top and along the side of the

cartridge (Figure 4). Grasp the cartridge by these

holes and slide the unit forward from the cabinet

until the cartridge is free. Use caution to ensure

that power and electrical cords do not get pinched

between the cartridge and cabinet while removing

cartridge.

„ TO LEVEL UNIT — The door is equipped with

gravity assisted cams and will not function properly

without proper leveling of cabinet. Adjust feet using

adjustable wrench so that unit sits approximately

level to floor and door closes properly. For best door

operation, adjust leveling feet so that cabinet has

a

1

/

16

-in. rake or slant from front to back. Optional

casters are available to replace leveling feet.
NOTE: If casters are not used, local codes may require

cabinet to be sealed around the perimeter of the cabi-

net base. Consult local sanitation codes. Use only seal-

ant material approved for this use, such as Dow

Corning #732.

Before servicing unit, disconnect electrical service.

On sizes 1100L and 1300L, turn disconnect switch

(located on power cord) to the OFF position. Failure

to disconnect electrical service could result in elec-

trical shock and cause personal injury or death.

CARTRIDGE POWER
AND LIGHTING CORDS

PULL THE CARTRIDGE USING
THE HANDLING HOLES ON SIDES

UNPLUG CARTRIDGE POWER
AND LIGHTING CORDS

FIGURE 2 — PREPARE CARTRIDGE FOR REMOVAL

FIGURE 3 — ROTATE LIFTING WIRES IN

DIRECTION SHOWN

FIGURE 4 — REMOVE CARTRIDGE

CUT WIRE TIE THAT SECURES
LIFTING RODS TO BASE

a79-2

a79-3

a79-4