beautypg.com

Maintenance, Lamp replacement, Condensate removal – Carrier Miracool 260L User Manual

Page 14: Condenser, Cabinet exterior, Interior surface

background image

14

MAINTENANCE

LAMP REPLACEMENT

Remove lamp by rotating lamp 90 degrees to align

lamp pins with holder slots. Refer to Bi-Pin Fluores-

cent lamp Installation/Verification section on page 6.

CONDENSATE REMOVAL

The evaporator drain pan is located in the base of the

cartridge. In general, the condensate disposal system

is maintenance free.

CONDENSER

The condenser should be inspected periodically for

accumulation of debris, which should be removed. A

vacuum cleaner or brush can be used to remove debris.

CABINET EXTERIOR

Cabinets should be cleaned with a solution of mild

soap and water or mild household cleaner. Do not use

caustic soap or abrasive cleaners, since these might

damage the cabinet finish. If stainless steel surface

becomes discolored, scrub by rubbing only in direction

of the finish grain. Do not use steel wool or rusting

may occur. Refer to Table 4.

INTERIOR SURFACE

The inside of the cabinet is coated with baked-on

epoxy. To clean, use a mild soap and water solution or

mild household cleaner.

Before proceeding with replacement, disconnect

electrical service. Failure to unplug unit could result

in serious personal injury or death.