37


Cellular Fault Detection: Alert generated when cellular prepaid balance < $5


A.8 Temperature Measurement

Type:

Onboard, internal to the enclosure, temperature IC

Accuracy:

+/- 5 degrees Fahrenheit

Reporting Resolution:

1 degree Fahrenheit, current and historic low, high





A.9 Local Summary Alarm Contacts

Type:

Relay, Type 1A Contacts


Operation:

Normally energized (contacts closed),

De-energized (contacts open) when a Fault
condition is present; or, manual control of

output contacts via DTMF command.


Contact Rating:

10 VA, Resistive Load

Max. Switch Current:

0.5 Amp D.C


Max Switch Voltage:

48 Volts D.C.


Max. Carry Current:

1.25 Amps D.C.


Isolation: