FTDI COM Port Trouble-Shooting








CLI measurement can be displayed in two different formats: decimal or hex. Both formats are returned as

ASCII character strings. The following figure uses CLI commands to return the same data presented in

the Auto-Reporting mode.

Refer to the applicable Firmware Description Document for a complete description of available CLI

commands and their invocation usage.

If the FTDI device driver did not install properly, there would be no assigned COM port

number for the FTDI controller. Repeat the USB Driver Installation, see Section 2.1.

Microsoft Windows may associate a Ball Point device to the FTDI USB controller. When this

occurs a FTDI device COM port assignment is available via HyperTerminal but there is no

communications data. Verify if a Ball Point device has been added to the “Human Interface

Devices” via the Device manager. Refer to Section 2.2 for access to the Device Manager. If

a Ball Point device exists, delete it and unplug and replug the evaluation board’s USB cable.

Use “?” for Decimal format

Use “$” for Hex format