All operating parameters are programmable from either the EntraGuard Bronze’s front panel
keypad or from any telephone in the residence connected to the same phone line as the
EntraGuard Bronze unit. There are 19 commands available. Listed below are some of the most
commonly used. For more information on programming the EntraGuard Bronze, refer to the
EntraGuard Bronze Quick Start Guide (P/N 01911-001).
When entering programming commands, the unit responds to correct entries with a short, high-
pitched tone to indicate the command was accepted. The unit responds to incorrect/invalid
entries with a short, high-pitched tone followed by a low-pitched tone to indicate the command
was rejected.
1530 Old Oakland Road, Suite 100
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]
Operation
Instructions
To Enter
Progrmming Mode
using Bronze Unit
See the EntraGuard
Bronze Residence
Guide for the pre-
programmed code.
Factory Default =
999999
• Press
.
• Press
– the six-digit programming
code.
• The unit emits a short high-pitched tone to indicate the unit is in programming
mode. If no sound is emitted an invalid programming code has been entered.
To Enter
Progrmming Mode
using Residence
Telephone
See the EntraGuard
Bronze Residence
Guide for the pre-
programmed code.
Factory Default =
999999
• Press
.
• Press
– the six-digit programming
code.
• The unit emits a short high-pitched tone to indicate the unit is in programming
mode. If no sound is emitted an invalid programming code has been entered.
All subsequent commands assume the EntraGuard Bronze unit is in Programming
Mode.
Add an Entry Code
The EntraGuard
Bronze comes with
four entry codes pre-
programmed. See the
EntraGuard Bronze
Residence Guide for
the codes.
Factory Default =
123
• Press
.
• Press
– the desired entry code.
• Press
. The unit emits a short high-pitched tone to indicate the code has
been accepted. A high-low tone is emitted if an invalid programming code has
been entered.
Delete an Entry
Code
• Press
.
• Press
– the entry code to be deleted.
• Press
. The unit emits a short high-pitched tone to indicate the code has
been deleted. A high-low tone is emitted if an invalid entry code has been
entered.
Delete all Entry
Codes
• Press
.
• Press
. The unit emits a short high-pitched tone to indicate all entry codes
have been deleted. A high-low tone is emitted if an invalid entry code has been
entered.
Reset the
EntraGuard Bronze
Unit
• Press
.
• Press
. The unit emits a short high-pitched tone to indicate the unit has
been reset.
Set the Programming
Mode Entry Code
See the EntraGuard
Bronze Residence
Guide for the pre-
programmed code.
Factory Default =
999999
• Press
.
•
Press
–
the
desired
six-digit
programming code.
• Press
. The unit emits a short high-pitched tone to indicate the entry code
has been accepted. A high-low tone is emitted if an invalid entry code has been
entered.
Set the Ring Mode
The EntraGuard
Bronze has been pre-
programmed to Type
2.
Factory Default =
Type 1
• Press
.
• Press
– the desired ring mode.
• Type 1: three short rings - long pause
• Type 2: two medium rings - long pause
• Press
. The unit emits a short high-pitched tone to indicate the ring mode
has been accepted. A high-low tone is emitted if an invalid ring mode has been
entered.
Set the Maximum
Number of Rings
Factory Default = 6
• Press
.
• Press
– the desired number of rings.
• Press
. The unit emits a short high-pitched tone to indicate the number of
rings has been accepted. A high-low tone is emitted if an invalid number of rings
has been entered.
Set Gate 1 Relay
Access Code
Factory Default = 9
• Press
.
• Press
– the desired relay access code.
• Press
. The unit emits a short high-pitched tone to indicate the access code
has been accepted. A high-low tone is emitted if an invalid access code has been
entered.
Set Gate 1 Relay
Timeout
Factory Default = 5
seconds
• Press
.
• Press
– the desired relay timeout value.
• Press
. The unit emits a short high-pitched tone to indicate the timeout
value has been accepted. A high-low tone is emitted if an invalid timeout value
has been entered.
Set Gate 2 Relay
Access Code
Factory Default = 2
• Press
.
• Press
– the desired relay access code.
• Press
. The unit emits a short high-pitched tone to indicate the access code
has been accepted. A high-low tone is emitted if an invalid access code has been
entered.
Operation
Instructions
Set Gate 2 Relay
Timeout
Factory Default = 5
seconds
•
Press .
• Press
– the desired relay timeout value.
• Press
. The unit emits a short high-pitched tone to indicate the timeout
value has been accepted. A high-low tone is emitted if an invalid timeout value
has been entered.
Set Call Forwarding
Telephone Number
•
Press .
•
Press
–
the
desired
forwarding
telephone number (up to 20 digits).
• Press
. The unit emits a short high-pitched tone to indicate the telephone
number has been accepted. A high-low tone is emitted if an invalid telephone
number has been entered.
Enable Call
Forwarding
•
Press .
• Press
. The unit emits a short high-pitched tone to indicate call forwarding
has been enabled.
Disable Call
Forwarding
•
Press .
• Press
. The unit emits a short high-pitched tone to indicate call forwarding
has been disabled.
Set Maximum
Connection Time
Factory Default = 60
seconds
•
Press .
• Press
– the desired maximum connection time.
• Press
. The unit emits a short high-pitched tone to indicate the connection
time has been accepted. A high-low tone is emitted if an invalid connection time
has been entered.
Operation
Instructions