3. EP1501 Wiring and Setup:

EP1501 CONNECTIONS

TB1-1

IN1

Input 1

TB1-2

IN1

TB1-3

IN2

Input 2

TB1-4

IN2

TB2-1

VO

Reader 1 Power Output

– 12 Vdc

TB2-2

LED

Reader 1 LED Output

TB2-3

BZR

Reader 1 Buzzer Output

TB2-4

CLK

Reader 1 CLK/Data 1/TR+

TB2-5

DAT

Reader 1 DAT/Data 0/TR-

TB2-6

GND

Reader 1 Ground

TB3-1

LED

Reader 2 LED Output

TB3-2

BZR

Reader 2 Buzzer Output

TB3-3

CLK

Reader 2 CLK/Data 1 Input

TB3-4

DAT

Reader 2 DAT/Data 0 Input

TB4-1

VO

Auxiliary Power Output

– 12 Vdc

TB4-2

GND

Auxiliary Power Output Ground

TB4-3

VIN

Input Power

– 12 Vdc (from local power supply)

TB4-4

GND

Input Power Ground

TB5-1

NO

Relay K1

– Normally Open Contact

TB5-2

1-C

Relay K1

– Common Contact

TB5-3

NC

Relay K1

– Normally Closed Contact

TB5-4

NO

Relay K2

– Normally Open Contact

TB5-5

2-C

Relay K2

– Common Contact

TB5-6

NC

Relay K2

– Normally Closed Contact

Jumpers:

JUMPERS SET AT

DESCRIPTION

J1

N/A

Factory Use Only

J2

N/A

Factory Use Only

J3

PoE

EP1501 powered from the Ethernet connection

12V

EP1501 powered from an local 12 Vdc power source
connected to TB4-3 (VIN), TB4-4 (GND)

J4

N/A

Factory Use Only

J5

N/A

Factory Use Only

J6

N/A

10-Base-T/100Base-TX Ethernet Connection

J7

Cabinet Tamper Switch Input: short = tamper secure