2 design 5 pxl-100 connections, Ms-4000: shootingstar reader, Quick s tart guide ms-4000 – Keri Systems MS-4000 User Manual
Page 4
MS-4000: ShootingStar Reader
2305 Bering Drive
01815-004 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]
Page 4 of 8
Quick S
tart Guide
MS-4000
3.2
Design 5 PXL-100 Connections
The "A" reader connects to TB2, pins 14 through 19. The "B" reader connects to TB3, pins 20
through 25.
Connecting the PXL-100 – TB2 Connecting to the PXL-100 – TB3
Figure 3: Design 5 PXL-100 Connections
NOTE: Please contact customer support at Keri Systems for information regarding connecting a
Reader to a Design 4 PXL-100. A Design 4 PXL-100 can be identified by the location of its power
connection made at the middle of the left edge of the printed circuit board.
Pin #
Function
Wire Color
Pin #
Function
Wire Color
14
no connection
–
20
no connection
–
15
no connection
–
21
no connection
–
16
Reader Power
Red
22
Reader Power
Red
17
Reader Ground
Black
23
Reader Ground
Black
17
Shield
Silver
23
Shield
Silver
18
Reader Antenna
Blue
24
Reader Antenna
Blue
19
no connection
–
25
no connection
–