1 pxl-250 connections, Ms-4000: shootingstar reader, Ms-4000 quick s tart guide – Keri Systems MS-4000 User Manual
Page 3
MS-4000: ShootingStar Reader
2305 Bering Drive
01815-004 Rev. G
San Jose, CA 95131 USA
(800) 260-5265 (408) 435-8400 FAX (408) 577-1792
Web: www.kerisys.com E-mail: [email protected]
Page 3 of 8
MS-4000
Quick S
tart Guide
3.1
PXL-250 Connections
The "A" reader connects to TB5, pins 1, 3 and 4 (no connection is made to pins 2, 5, 6, and 7).
The "B" reader connects to TB6 pins 1, 3 and 4 (no connection is made to pins 2, 5, 6, and 7).
Connecting to the PXL-250 – TB5 or TB6
Figure 2: PXL-250 Connections
Pin #
Function
Wire Color
1
Reader Antenna
Blue
2
no connection
–
3
Reader Power
Red
4
Reader Ground
Black
4
Shield
Silver
5
no connection
–
6
no connection
–
7
no connection
–