beautypg.com

Tap controller block diagram, Tap electrical characteristics – Cypress CY7C1425AV18 User Manual

Page 15

background image

CY7C1410AV18, CY7C1425AV18
CY7C1412AV18, CY7C1414AV18

Document #: 38-05615 Rev. *E

Page 15 of 29

TAP Controller Block Diagram

TAP Electrical Characteristics

Over the Operating Range

[10, 11, 12]

Parameter

Description

Test Conditions

Min

Max

Unit

V

OH1

Output HIGH Voltage

I

OH

=

−2.0 mA

1.4

V

V

OH2

Output HIGH Voltage

I

OH

=

−100 μA

1.6

V

V

OL1

Output LOW Voltage

I

OL

= 2.0 mA

0.4

V

V

OL2

Output LOW Voltage

I

OL

= 100

μA

0.2

V

V

IH

Input HIGH Voltage

0.65V

DD

V

DD

+ 0.3

V

V

IL

Input LOW Voltage

–0.3

0.35V

DD

V

I

X

Input and Output Load Current

GND

≤ V

I

≤ V

DD

–5

5

μA

0

0

1

2

.

.

29

30

31

Boundary Scan Register

Identification Register

0

1

2

.

.

.

.

108

0

1

2

Instruction Register

Bypass Register

Selection

Circuitry

Selection

Circuitry

TAP Controller

TDI

TDO

TCK

TMS

Notes

10. These characteristics pertain to the TAP inputs (TMS, TCK, TDI and TDO). Parallel load levels are specified in the

Electrical Characteristics

table.

11. Overshoot: V

IH

(AC) < V

DDQ

+ 0.85V (Pulse width less than t

CYC

/2), Undershoot: V

IL

(AC) >

1.5V (Pulse width less than t

CYC

/2).

12. All Voltage referenced to Ground.

[+] Feedback

This manual is related to the following products: