beautypg.com

Device setup troubleshooting, Table 4-7 – Cabletron Systems 6H203-24 User Manual

Page 48

background image

Troubleshooting Checklist

4-10

Troubleshooting

Table 4-7

Device Setup Troubleshooting

Possible Causes

Instruction

The module detects a
looped condition.

1. Verify that Spanning Tree is enabled. Refer to the Local

Management User’s Guide for instructions on setting the type
of STA.

2. Review network design and delete unnecessary loops.

Mode switch (7),
NVRAM Reset, was
changed sometime before
either cycling power or
pressing the RESET
button, causing the user-
entered parameters to
reset to factory default
settings.

1. Reenter the lost parameters as necessary. Refer to your Local

Management User’s Guide for instructions on configuring the
device through Local Management.

2. Call Cabletron Systems if the problem continues.

Clear NVRAM was set
through Local
Management.

1. Reenter the lost parameters as necessary. Refer to the Local

Management User’s Guide for instructions on configuring the
device through Local Management.

2. Call Cabletron Systems if the problem continues.

NOTE

If these troubleshooting tables do not solve any problems that occur with the 6H203-24
or 6H253-13, contact Cabletron Systems. Refer to

Section 1.2

, for details.

This manual is related to the following products: