beautypg.com

Speed and full duplex led indications, Table 4-2 – Cabletron Systems 6H203-24 User Manual

Page 43

background image

Using LANVIEW

Troubleshooting

4-5

Table 4-2

Speed and Full Duplex LED Indications

TX

Off

Port enabled, and no
activity. Should flash green
every two seconds
indicating BPDUs being
sent if STA is enabled and
there is a valid link.

1. Ensure that the STA is enabled and that

there is valid link. The Local
Management User’s Guide
describes
how to enable the STA.

2. Contact Cabletron Systems.

Green

Flashing. Indicates
activity. Rate indicates data
rate.

None.

Amber

Blinking. Port in standby.

Port may be disabled due
to Spanning Tree.

1. Ensure that the port is not disabled.

Refer to the Local Management User’s
Guide
for information on enabling/
disabling ports.

2. Contact Cabletron Systems.

Red

Flashing. Indicates
collision rate.

None, unless there is a high rate of activity.
If so, check for network configuration
problems or a defective device.

Solid. Diagnostic Failure.

Contact Cabletron Systems.

LED

Color

Description

The following port DPX and SPD LED indications are only valid when the LED MODE
switch is in the DPX-SPD position.

DPX

(Duplex
Status)

Amber

Port is operating in standard mode (10 Mbps or 100 Mbps).

Green

Port is operating in full duplex mode (20 Mbps or 200 Mbps).

SPD
(Speed
Status)

Amber

There is a link and the port is operating at 10 Mbps.

Green

There is a link and the port is operating at 100 Mbps.

Table 4-1

LANVIEW LEDs CPU, Receive, and Transmit Status (Continued)

LED

Color

State

Recommended Action

This manual is related to the following products: