beautypg.com

Lanview leds cpu, receive, and transmit status, Table 4-1 – Cabletron Systems 6H203-24 User Manual

Page 42

background image

Using LANVIEW

4-4

Troubleshooting

Table 4-1

LANVIEW LEDs CPU, Receive, and Transmit Status

LED

Color

State

Recommended Action

CPU

Off

Power off.

Power up chassis.

Red

Blinking. Hardware failure
has occurred.

Contact Cabletron Systems.

Solid. Resetting, normal
power up reset.

If the LED remains red for several minutes,
contact Cabletron Systems.

Amber

Blinking. Crippled.

Contact Cabletron Systems.

Solid. Testing.

If the LED remains amber for several
minutes, contact Cabletron Systems.

Green

Solid. Functional.

None.

Amber
and
Green

Booting. Blinks amber and
green while booting.

None.

The following port RX and TX LED indications are only valid when the LED MODE switch is
in the RX-TX position.

RX

Off

No link. No activity or port
in Standby. Port enabled or
disabled.

None.

Green

Solid. Port enabled, link,
no activity.

None.

Blinking. Port disabled,
link.

Enable port if desired.

Amber

Flashing. Port enabled,
link, activity.

None.

Red

Diagnostic failure.

Contact Cabletron Systems.

This manual is related to the following products: