beautypg.com

Multi-tenant security system user guide, Additional commands for the 8 zone keypad only, 8 and 2 zone keypad light descriptions – Interlogix XL 4 Zone LCD User Manual

Page 11: Light display meanings

background image

Multi-Tenant Security System User Guide

22-9050 v1.3

MONITOR ISM™/AFx™ Multi-Tenant Security System User Guide

9

Additional Commands for the 8 Zone Keypad Only

Identifying a user’s ID number
After this command is entered, the user’s ID # (2-8, the master user usually being 1) will display on the 8
sensor zone lights. Example, if user’s PIN entered belongs to the 5

th

user, sensor zone light # 5 will turn

on. This feature identifies for the master user which user locations are vacant or can have their user PIN
erased, in order to add new users.

Press

then

then a Master PIN, then the User’s PIN whose user number you


want to check, 2 – 8.
The Ready, Armed and Trouble lights will flash and the user’s # light is on steady.
The indication will last 10 seconds or press

to reset the keypad back to normal operation.

Grant Lobby Access
If pre-arranged with Security Management, this command can send a signal to the building security main
desk, concierge, to authorize a visitor’s entrance.

Press

then

then a Master PIN.

8 and 2 Zone Keypad Light Descriptions

Light Display

Meanings

Trouble Triangle


Slow Flash

Fast Flash

On

On

System hydro mains power failure

Communication problem with building main control

equipment.

Possibly keypad base lose causing tamper alert.

(8 Zone Keypad only)

With fast flashing Sensor Zone(s), either keypad.

Sensor zone wiring faulty.

Incorrect sensor zone programming.

Check with your Security Representative.

System Okay

On
Off

Sensor Zones okay. System ready to arm.

Sensor zone(s) insecure or system is ON.

Armed

Off
On

Flashing

Protection

off.

Protection in STAY (remaining inside, no internal motion

detectors on, only doors and windows protected).

Protection

Fully

ON

Sensor Zones
1 – 8 (8 Zone Keypad)

1 and 2 (2 Zone)

Off
On

Slow Flash

Fast Flash

OK or protection ON.

Insecure or system in Walk Test.

Bypassed.

With Trouble light. Example: wiring fault.