Data Retention and Endurance

Parameter

Description

Min

Unit

DATA

R

Data Retention

100

Years

NV

C

Nonvolatile STORE Operations

1,000

K

Capacitance

In the following table, the capacitance parameters are listed.

[6]

Parameter

Description

Test Conditions

Max

Unit

C

IN

Input Capacitance

T

A

= 25

°C, f = 1 MHz,

V

CC

= 0 to 3.0 V

8

pF

C

OUT

Output Capacitance

7

pF

Thermal Resistance

In the following table, the thermal resistance parameters are listed.

[6]

Parameter

Description

Test Conditions

28-SOIC

28-PDIP

(300 mil)

28-PDIP

(600 mil)

28-CDIP

28-LCC

Unit

Θ

JA

Thermal Resis-
tance
(Junction to
Ambient)

Test conditions follow
standard test methods and
procedures for measuring
thermal impedance, per EIA /
JESD51.

46.55

45.16

55.84

46.1

95.31

°C/W

Θ

JC

Thermal Resis-
tance
(Junction to Case)

27.95

31.62

25.74

5.01

9.01

°C/W

Figure 6. AC Test Loads

AC Test Conditions

5.0V

Output

30 pF

R1 963

Ω

R2

512

Ω

5.0V

Output

5 pF

R1 963

Ω

R2

512

Ω

For Tri-state Specs

Input Pulse Levels .................................................. 0 V to 3 V
Input Rise and Fall Times (10% to 90%) ...................... <5 ns
Input and Output Timing Reference Levels .......................1.5

Note

6. These parameters are guaranteed by design and are not tested.