Hardware STORE Cycle

Parameter

Alt

Description

STK12C68

Unit

Min

Max

t

STORE

[9, 14]

t

HLHZ

STORE Cycle Duration

10

ms

t

DHSB

[14, 19]

t

RECOVER,

t

HHQX

Hardware STORE High to Inhibit Off

700

ns

t

PHSB

t

HLHX

Hardware STORE Pulse Width

15

ns

t

HLBL

Hardware STORE Low to STORE Busy

300

ns

Switching Waveform