15.5.2 G-Series Ethernet Card Performance Monitoring Parameters
15.5.2.1 G-Series Ethernet Statistics Window
The Ethernet statistics window lists Ethernet parameters at the line level. The Statistics window provides
buttons to change the statistical values shown. The Baseline button resets the displayed statistics values
to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which
automatic refresh occurs. The G-Series Statistics window also has a Clear button. The Clear button sets
the values on the card to zero, but does not reset the G-Series card.
defines the G-Series Ethernet card Statistics parameters.
Table 15-18 G-Series Ethernet Statistics Parameters
Parameter
Meaning
Time Last Cleared
A time stamp indicating the last time statistics were reset.
Link Status
Indicates whether the Ethernet link is receiving a valid
Ethernet signal (carrier) from the attached Ethernet device;
up means present, and down means not present.
Rx Packets
Number of packets received since the last counter reset.
Rx Bytes
Number of bytes received since the last counter reset.
Tx Packets
Number of packets transmitted since the last counter reset.
Tx Bytes
Number of bytes transmitted since the last counter reset.
Rx Total Errors
Total number of receive errors.
Rx FCS
Number of packets with a Frame Check Sequence (FCS)
error. FCS errors indicate frame corruption during
transmission.
Rx Alignment
Number of packets with received incomplete frames.
Rx Runts
Measures undersized packets with bad cyclic redundancy
check (CRC) errors.
Rx Shorts
Measures undersized packets with good cyclic redundancy
check (CRC) errors.
Rx Jabbers
Total number of frames received that exceed the 1548-byte
maximum and contain CRC errors.
Rx Giants
Number of packets received that are greater than 1530 bytes
in length.
Rx Pause Frames
Number of received Ethernet IEEE 802.3z pause frames.
Tx Pause Frames
Number of transmitted IEEE 802.3z pause frames.
Rx Pkts Dropped Internal
Congestion
Number of received packets dropped due to overflow in
G-Series frame buffer.
Tx Pkts Dropped Internal
Congestion
Number of transmit queue drops due to drops in the G-Series
frame buffer.
HDLC Errors
High-level data link control (HDLC) errors received from
SDH/SONET (see note).
Rx Unicast Packets
Number of unicast packets received since the last counter
reset.
Tx Unicast Packets
Number of unicast packets transmitted.